39 free function blocks (ffb), Issue 01/06 parameter description, P2800 enable ffbs – Siemens 440 User Manual

Page 241

Advertising
background image

Issue 01/06

Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

241

3.39

Free function blocks (FFB)

P2800 Enable

FFBs

Min: 0

CStat:

CUT

Datatype: U16 Unit:

-

Def:

0

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 1

Free function blocks (FFB) are enabled in two steps.
1. Parameter P2800 enables all free function blocks , normally (P2800 = 1).
2. Parameters P2801 and P2802 respectively, enable each free function block individually (P2801[x] > 0

oder P2802[x] > 0).

Possible Settings:

0 Disabled
1 Enabled

Dependency:

All active function blocks will be calculated in every 132 ms.

P2801[17] Activate

FFBs

Min: 0

CStat:

CUT

Datatype: U16 Unit:

-

Def:

0

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 3

Free function blocks (FFB) are enabled in two steps.
1. Parameter P2800 enables all free function blocks , normally (P2800 = 1)
2. Parameters P2801 and P2802 respectively, enable each free function block individually (P2801[x] > 0

oder P2802[x] > 0)


In addition, Parameters P2801 and P2802 determine the chronological order of each function block. The
following table shows that the priority increases from left to right and from bottom to top.

3
2
1
0

P28

02 [1

3]

C

M

P

2

P28

02 [1

2]

C

M

P

1

P2

80

2 [

11]

D

IV

2

P2

80

2 [

10]

D

IV

1

P

2802 [

9

]

M

U

L

2

P

2802 [

8

]

M

U

L

1

P2

80

2 [7

]

S

U

B

2

P2

80

2 [6

]

S

U

B

1

P28

0

2 [5

]

ADD 2

P28

0

2 [4

]

ADD 1

P2

80

2 [3

]

T

im

er

4

P2

80

2 [2

]

T

im

er

3

P2

80

2 [1

]

T

im

er

2

P2

80

2 [0

]

T

im

er

1

P

2

80

1

[16]

RS-F

F

3

P

2

80

1

[15]

RS-F

F

2

P

2

80

1

[14]

RS-F

F

1

P

2

80

1 [

13]

D

-F

F

2

P

2

80

1 [

12]

D

-F

F

1

P

2

80

1

[11]

NOT

3

P

2

80

1

[10]

NOT

2

P28

01 [9

]

NOT 1

P28

01 [8

]

XOR 3

P28

01 [7

]

XOR 2

P28

01 [6

]

XOR 1

P28

01 [5

]

OR

3

P28

01 [4

]

OR

2

P28

01 [3

]

OR

1

P28

0

1 [2

]

AND 3

P28

0

1 [1

]

AND 2

P28

0

1 [0

]

AND 1

Level
Level

Level
Inactive

low

high

Pri

or

ity

1

Priority 2

low

Possible Settings:

0 Not

Active

1 Level

1

2 Level

2

3 Level

3

Index:

P2801[0] : Enable AND 1
P2801[1] : Enable AND 2
P2801[2] : Enable AND 3
P2801[3] : Enable OR 1
P2801[4] : Enable OR 2
P2801[5] : Enable OR 3
P2801[6] : Enable XOR 1
P2801[7] : Enable XOR 2
P2801[8] : Enable XOR 3
P2801[9] : Enable NOT 1
P2801[10] : Enable NOT 2
P2801[11] : Enable NOT 3
P2801[12] : Enable D-FF 1
P2801[13] : Enable D-FF 2
P2801[14] : Enable RS-FF 1
P2801[15] : Enable RS-FF 2
P2801[16] : Enable RS-FF 3

Example:

P2801[3] = 2, P2801[4] = 2, P2802[3] = 3, P2802[4] = 2
FFBs will be calculated in following order:
P2802[3], P2801[3] , P2801[4], P2802[4]

Dependency:

-

Set P2800 to 1 to enable function blocks.

-

All active function blocks will be calculated in every 132 ms.