Siemens 440 User Manual

Page 54

Advertising
background image

Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

54

6SE6400-5BB00-0BP0

r0313[3]

Motor pole pairs

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: MOTOR

Max: -

Displays number of motor pole pairs that the inverter is currently using for internal calculations.

Index:

r0313[0] : 1st. Drive data set (DDS)
r0313[1] : 2nd. Drive data set (DDS)
r0313[2] : 3rd. Drive data set (DDS)

Value:

r0313 = 1 : 2-pole motor
r0313 = 2 : 4-pole motor
etc.

Dependency:

Recalculated automatically when P0310 (rated motor frequency) or P0311 (rated motor speed) is changed.

P0311

P0310

60

r0313

=

P0314[3]

Motor pole pair number

Min: 0

CStat:

C

Datatype: U16 Unit:

-

Def:

0

P-Group: MOTOR

Active: first confirm

QuickComm.: Yes Max: 99

Specifies number of pole pairs of motor.

Index:

P0314[0] : 1st. Drive data set (DDS)
P0314[1] : 2nd. Drive data set (DDS)
P0314[2] : 3rd. Drive data set (DDS)

Value:

P0314 = 1 : 2-pole motor
P0314 = 2 : 4-pole motor
etc.

Dependency:

Recalculated automatically when P0310 (rated motor frequency) or P0311 (rated motor speed) is changed.

P0320[3]

Motor magnetizing current

Min: 0.0

CStat:

CT

Datatype: Float Unit:

%

Def:

0.0

P-Group: MOTOR

Active: Immediately

QuickComm.: Yes Max: 99.0

Defines motor magnetization current in [%] relative to P0305 (rated motor current).

Index:

P0320[0] : 1st. Drive data set (DDS)
P0320[1] : 2nd. Drive data set (DDS)
P0320[2] : 3rd. Drive data set (DDS)

Dependency:

Setting P0320 = 0: causes calculation by
-

P0340 = 1 (data entered from rating plate) or by

-

P3900 = 1 - 3 (end of quick commissioning). The calculated value is displayed in parameter r0331.

r0330[3]

Rated motor slip

Min: -

Datatype: Float Unit:

%

Def:

-

P-Group: MOTOR

Max: -

Displays nominal motor slip in [%] relative to P0310 (rated motor frequency) and P0311 (rated motor
speed).

%

100

P0310

r0313

60

P0311

P0310

[%]

r0330

=

Index:

r0330[0] : 1st. Drive data set (DDS)
r0330[1] : 2nd. Drive data set (DDS)
r0330[2] : 3rd. Drive data set (DDS)

r0331[3]

Rated magnetization current

Min: -

Datatype: Float Unit:

A

Def:

-

P-Group: MOTOR

Max: -

Displays calculated magnetizing current of motor in [A].

Index:

r0331[0] : 1st. Drive data set (DDS)
r0331[1] : 2nd. Drive data set (DDS)
r0331[2] : 3rd. Drive data set (DDS)

Level

3

Level

3

Level

3

Level

3

Level

3

Advertising