Siemens 440 User Manual

Page 160

Advertising
background image

Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

160

6SE6400-5BB00-0BP0

P1321[3]

Programmable V/f volt. coord. 1

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

V

Def:

0.0

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 3000.0

See P1320 (programmable V/f freq. coord. 1).

Index:

P1321[0] : 1st. Drive data set (DDS)
P1321[1] : 2nd. Drive data set (DDS)
P1321[2] : 3rd. Drive data set (DDS)

P1322[3]

Programmable V/f freq. coord. 2

Min: 0.00

CStat:

CT

Datatype: Float Unit:

Hz

Def:

0.00

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 650.00

See P1320 (programmable V/f freq. coord. 1).

Index:

P1322[0] : 1st. Drive data set (DDS)
P1322[1] : 2nd. Drive data set (DDS)
P1322[2] : 3rd. Drive data set (DDS)

P1323[3]

Programmable V/f volt. coord. 2

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

V

Def:

0.0

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 3000.0

See P1320 (programmable V/f freq. coord. 1).

Index:

P1323[0] : 1st. Drive data set (DDS)
P1323[1] : 2nd. Drive data set (DDS)
P1323[2] : 3rd. Drive data set (DDS)

P1324[3]

Programmable V/f freq. coord. 3

Min: 0.00

CStat:

CT

Datatype: Float Unit:

Hz

Def:

0.00

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 650.00

See P1320 (programmable V/f freq. coord. 1).

Index:

P1324[0] : 1st. Drive data set (DDS)
P1324[1] : 2nd. Drive data set (DDS)
P1324[2] : 3rd. Drive data set (DDS)

P1325[3]

Programmable V/f volt. coord. 3

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

V

Def:

0.0

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 3000.0

See P1320 (programmable V/f freq. coord. 1).

Index:

P1325[0] : 1st. Drive data set (DDS)
P1325[1] : 2nd. Drive data set (DDS)
P1325[2] : 3rd. Drive data set (DDS)

P1330[3]

CI: Voltage setpoint

Min: 0:0

CStat:

T

Datatype: U32 Unit:

-

Def:

0:0

P-Group: CONTROL

Active: first confirm

QuickComm.: No

Max: 4000:0

BICO parameter for selecting source of voltage setpoint for independent V/f control.

Index:

P1330[0] : 1st. Command data set (CDS)
P1330[1] : 2nd. Command data set (CDS)
P1330[2] : 3rd. Command data set (CDS)

Level

3

Level

3

Level

3

Level

3

Level

3

Level

3

Advertising