Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

40

6SE6400-5BB00-0BP0

r0075

CO: Current setpoint Isd

Min: -

Datatype: Float Unit:

A

Def:

-

P-Group: CONTROL

Max: -

Displays setpoint of flux generating current component.

Dependency:

Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.

r0076

CO: Act. current Isd

Min: -

Datatype: Float Unit:

A

Def:

-

P-Group: CONTROL

Max: -

Displays flux generating current component.

Dependency:

Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.

r0077

CO: Current setpoint Isq

Min: -

Datatype: Float Unit:

A

Def:

-

P-Group: CONTROL

Max: -

Displays setpoint for component of torque generating current.

Dependency:

Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.

r0078

CO: Act. current Isq

Min: -

Datatype: Float Unit:

A

Def:

-

P-Group: CONTROL

Max: -

Displays component of torque generating current.

r0079

CO: Torque setpoint (total)

Min: -

Datatype: Float Unit:

Nm

Def:

-

P-Group: CONTROL

Max: -

Displays total torque setpoint.

Dependency:

Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.

r0080

CO: Act. torque

Min: -

Datatype: Float Unit:

Nm

Def:

-

P-Group: CONTROL

Max: -

Displays actual torque. Output value will be zero at low frequencies when current injection is active (r1751.5
= 1).

r0084

CO: Act. air gap flux

Min: -

Datatype: Float Unit:

%

Def:

-

P-Group: CONTROL

Max: -

Displays air gap flux in [%] relative to the rated motor flux.

r0086

CO: Act. active current

Min: -

Datatype: Float Unit:

A

Def:

-

P-Group: CONTROL

Max: -

Displays active (real part) of motor current.

Dependency:

Applies when V/f control is selected in P1300 (control mode); otherwise, the display shows the value zero.

r0090

CO: Act. rotor angle

Min: -

Datatype: Float Unit:

°

Def:

-

P-Group: CONTROL

Max: -

Indicates the current angle of the rotor. This function is not available on single input channel encoders.

Level

3

Level

3

Level

3

Level

3

Level

3

Level

4

Level

4

Level

3

Level

2