P1336[3] Slip

limit

Min: 0

CStat:

CUT

Datatype: U16 Unit:

%

Def:

250

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 600

Compensation slip limit in [%] relative to r0330 (rated motor slip), which is added to frequency setpoint.

Index:

P1336[0] : 1st. Drive data set (DDS)
P1336[1] : 2nd. Drive data set (DDS)
P1336[2] : 3rd. Drive data set (DDS)

Dependency:

Slip compensation (P1335) active.

r1337

CO: V/f slip frequency

Min: -

Datatype: Float Unit:

%

Def:

-

P-Group: CONTROL

Max: -

Displays actual compensated motor slip as [%]

Dependency:

Slip compensation (P1335) active.

3.29.1.2 Resonance

damping

P1338[3]

Resonance damping gain V/f

Min: 0.00

CStat:

CUT

Datatype: Float Unit:

-

Def:

0.00

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 10.00

Defines resonance damping gain for V/f. Here, di/dt of the acitve current will be scaled by P1338 (see
diagram below). If di/dt increases the resonance damping circuit decreases the inverter output frequency.

P1338

T

1338

P

f

i

-

active

res damping

Index:

P1338[0] : 1st. Drive data set (DDS)
P1338[1] : 2nd. Drive data set (DDS)
P1338[2] : 3rd. Drive data set (DDS)

Note:

-

The resonance damping function is used to dampen oscillations in the active current. These especially
occur when rotating field motors are operating under no-load conditions. The parameter is not used to
optimize the stabilizing behavior.

-

In the V/f control modes (refer to P1300), the resonance damping controller is activate in a range from
approximately 5 % up to 70 % of the rated motor frequency (P0310).

-

An excessively high value results in instability (positive feedback).