Siemens 440 User Manual

Page 63

Advertising
background image

Issue 01/06

Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

63

P0364[3]

Magnetizing curve flux 3

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

%

Def:

115.0

P-Group: MOTOR

Active: Immediately

QuickComm.: No

Max: 300.0

Specifies third flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).

Index:

P0364[0] : 1st. Drive data set (DDS)
P0364[1] : 2nd. Drive data set (DDS)
P0364[2] : 3rd. Drive data set (DDS)

Details:

See P0362 (magnetizing curve flux 1).

P0365[3]

Magnetizing curve flux 4

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

%

Def:

125.0

P-Group: MOTOR

Active: Immediately

QuickComm.: No

Max: 300.0

Specifies fourth flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).

Index:

P0365[0] : 1st. Drive data set (DDS)
P0365[1] : 2nd. Drive data set (DDS)
P0365[2] : 3rd. Drive data set (DDS)

Details:

See P0362 (magnetizing curve flux 1).

P0366[3]

Magnetizing curve imag 1

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

%

Def:

50.0

P-Group: MOTOR

Active: Immediately

QuickComm.: No

Max: 500.0

Specifies first magnetizing current value of the saturation characteristic in [%] relative to the rated
magnetizing current (P0331).

Index:

P0366[0] : 1st. Drive data set (DDS)
P0366[1] : 2nd. Drive data set (DDS)
P0366[2] : 3rd. Drive data set (DDS)

Dependency:

Affects P0320 (motor magnetizing current).

Details:

See P0362 (magnetizing curve flux 1).

P0367[3]

Magnetizing curve imag 2

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

%

Def:

75.0

P-Group: MOTOR

Active: Immediately

QuickComm.: No

Max: 500.0

Specifies second magnetizing current value of saturation characteristic in [%] relative to rated magnetizing
current (P0331).

Index:

P0367[0] : 1st. Drive data set (DDS)
P0367[1] : 2nd. Drive data set (DDS)
P0367[2] : 3rd. Drive data set (DDS)

Dependency:

Affects P0320 (motor magnetizing current).

Details:

See P0362 (magnetizing curve flux 1).

P0368[3]

Magnetizing curve imag 3

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

%

Def:

135.0

P-Group: MOTOR

Active: Immediately

QuickComm.: No

Max: 500.0

Specifies third magnetizing current value of saturation characteristic in [%] relative to rated magnetizing
current (P0331).

Index:

P0368[0] : 1st. Drive data set (DDS)
P0368[1] : 2nd. Drive data set (DDS)
P0368[2] : 3rd. Drive data set (DDS)

Dependency:

Affects P0320 (motor magnetizing current).

Details:

See P0362 (magnetizing curve flux 1).

Level

4

Level

4

Level

4

Level

4

Level

4

Advertising