Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 101

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

101

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

Case 2:

Axis activates reference switch first on the way to the limit switch:

1. Movement in negative direction with profile data set 1.
2. Positive edge of the reference switch activates profile data set 2.
3. Negative edge of the reference switch activates touch probe detection.
4. The following positive edge of the encoder zero pulse/touch probe sensor sets the

reference (

0x607C

).

5. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

Case 3:

Axis already stands on reference switch:

1. Movement in negative direction with profile data set 2.
2. Negative edge of the reference switch activates touch probe detection.
3. The following positive edge of the encoder zero pulse/touch probe sensor sets the

reference (

0x607C

).

4. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

CiA402 Homing method 15

Reserved: Homing is not carried out.

CiA402 Homing method 16

Reserved: Homing is not carried out.

Advertising