3 attribute table, Attribute table, Parameter reference attribute table – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 220

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter reference

Attribute table

220

L

EDS94TA11010xxxx EN 1.2 - 03/2010

5.3

Attribute table

The Attribute table contains information required for communicating with the controller

via parameters.

How to read the table of attributes:

Attribute table

Column

Meaning

Entry

Code

Parameter designation

Cxxxxx

Name

Short parameter text (display text)

Text

Index

dec

Index under which the parameter is addressed.

The subindex of array variables corresponds to the

Lenze subcode number.

24575 - Lenze code number

Only required for access via bus

system.

hex

5FFF

h

- Lenze code number

Data

DS

Data structure

E

Single variable

(only one parameter element)

A

Array variable

(several parameter elements)

DA

Number of array elements (subcodes)

Number

DT

Data type

BITFIELD_8

1 byte bit-coded

BITFIELD_16

2 bytes bit-coded

BITFIELD_32

4 bytes bit-coded

INTEGER_8

1 byte with sign

INTEGER_16

2 bytes with sign

INTEGER_32

4 bytes with sign

UNSIGNED_8

1 byte without sign

UNSIGNED_16

2 bytes without sign

UNSIGNED_32

4 bytes without sign

VISIBLE_STRING

ASCII string

Factor

Factor for data transmission via bus system,

depending on the number of decimal positions

Factor

1 ≡ no decimal positions

10 ≡ 1 decimal position

100 ≡ 2 decimal positions

1000 ≡ 3 decimal positions

Access

R

Read access

;

Reading allowed

W

Write access

;

Writing allowed

CINH

Controller inhibit required

;

Writing only possible when controller is inhibited

Code

Name

Index

Data

Access

dec

hex

DS

DA

DT

Factor

R

W

CINH

C03001

UG min threshold

21574

5446

E

1

INTEGER_32

100

;

;

C03002

Selection of limiter / safety

interconnection

21573

5445

E

1

UNSIGNED_8

1

;

;

C03010

Max. telegram failure value

21565

543D

E

1

UNSIGNED_32

1

;

;

C03011

Counter SingleError

21564

543C

E

1

INTEGER_32

1

;

C03012

Counter MultiError

21563

543B

E

1

INTEGER_32

1

;

C03013

Reset Errorcounter

21562

543A

E

1

UNSIGNED_8

1

;

;

C03500

CiA402 profile

21075

5253

E

1

UNSIGNED_32

1

;

C03503

Motor type

21072

5250

E

1

UNSIGNED_16

1

;

;

C03504

Motor catalogue number

21071

524F

E

1

VISIBLE_STRING

1

;

;

C03505

Motor manufacturer

21070

524E

E

1

VISIBLE_STRING

1

;

;

C03506

http motor catalogue address

21069

524D

E

1

VISIBLE_STRING

1

;

;

C03507

Motor calibration date

21068

524C

E

1

VISIBLE_STRING

1

;

;

C03508

Motor service period

21067

524B

E

1

UNSIGNED_32

1

;

;

C03509

Motor data

21066

524A

E

1

UNSIGNED_32

1

;

Advertising