Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 105

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

105

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

CiA402 Homing method 21

Processes:

Case 1:

Axis has not yet activated reference switch:

1. Movement in negative direction with profile data set 1.
2. Reversing with positive edge of the reference switch and change to profile data set 2.
3. The following negative edge of reference switch sets reference (

0x607C

).

4. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

Case 2:

Axis already stands on reference switch:

1. Movement in positive direction with profile data set 2.
2. The following negative edge of reference switch sets reference (

0x607C

).

3. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

 Homing switch

1

2

0

Advertising