9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Device control

3.7.3.8

Fault

If a grave error occurs, i.e. the drive is not able to operate the motor in a controlled manner

anymore, the drive is switched off immediately and this device state becomes active.

 The pulse inhibit is set, i.e. the pulses of the controller are inhibited.
 The motor is torqueless.
 The motor brake, if available, is closed.
 The operation is inhibited.
 The controller can be parameterised.

Bit pattern for the "Fault" device state in

0x6041

(status word):

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Warning

Switch on

disabled

Quick stop

Voltage

enabled

Fault

Operation

enabled

Switched on

Ready to switch

on

X

0

X

X

1

0

0

0

Note!

This device state can only be left using the "

Reset fault

" command if the error

cause is removed.