0x60b0, 0x607a, Objects described in this chapter – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 144

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Cyclic synchronous position mode (IEC 61800-7)

144

L

EDS94TA11010xxxx EN 1.2 - 03/2010

Objects described in this chapter:

0x607A - Target position

0x60B0 - Offset position

Index

Name

Data type

Object type

0x607A

Target position

INTEGER_32

VAR

0x60B0

Offset position

INTEGER_32

VAR

Grayed out = read access only

Index | Name:

0x607A | Target position

Data type: INTEGER_32

Code:

C03690

Position setpoint
Setting range

(min. value | unit | max. value)

Lenze setting

-2147483648

unit

2147483647 0 unit

;

Read access ; Write access … CINH … PLC-STOP ; PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x60B0 | Offset position

Data type: INTEGER_32

Code:

C03691

Additive value to the position setpoint
Setting range

(min. value | unit | max. value)

Lenze setting

-2147483648

unit

2147483647 0 unit

;

Read access ; Write access … CINH … PLC-STOP ; PDO_MAP_RX … PDO_MAP_TX