8 overview of cia402 homing modes, Overview of cia402 homing modes, Parameter setting & configuration homing mode – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 82: 8 overview of cia402 homing modes short overview

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

82

L

EDS94TA11010xxxx EN 1.2 - 03/2010

3.9.8

Overview of CiA402 homing modes

Short overview

CiA402 homing

method

Evaluated signals/sensors

Encoder zero pulse/

touch probe sensor

Negative

travel range limit switch

Positive

travel range limit switch

Reference switch

-2

Positive direction of rotation at torque limit.

-1

Negative direction of rotation at torque limit.

01

;

;

02

;

;

03

;

;

04

;

;

05

;

;

06

;

;

07

;

;

;

08

;

;

;

09

;

;

;

10

;

;

;

11

;

;

;

12

;

;

;

13

;

;

;

14

;

;

;

15

Reserved: Homing is not carried out.

16

Reserved: Homing is not carried out.

17

;

18

;

19

;

20

;

21

;

22

;

23

;

;

24

;

;

25

;

;

26

;

;

27

;

;

28

;

;

29

;

;

30

;

;

31

Reserved: Homing is not carried out.

32

Reserved: Homing is not carried out.

33

;

34

;

35

Direct reference setting.