15 touch probe, 1 input and output data, 2 object description – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 166: Touch probe, Input and output data, Object description, Touch probe ( 166)

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Touch probe

166

L

EDS94TA11010xxxx EN 1.2 - 03/2010

3.15

Touch probe

Up to 2 touch probe channels can be used in parallel.

 Possible touch probe sources:

– TP1 : Zero pulse position encoder or digital input DI7
– TP2 : Zero pulse position encoder or digital input DI8

Configuration: see control word

0x60B8

(Touch probe function)

3.15.1

Input and output data

Input data

Output data

3.15.2

Object description

Objects described in this chapter:

Index

Name

Data type

Object type

0x60B8

Touch probe function

UNSIGNED_16

VAR

Index

Name

Data type

Object type

0x60B9

Touch probe status

UNSIGNED_16

VAR

0x60BA

Touch probe pos 1 pos value

INTEGER_32

VAR

0x60BB

Touch probe pos 1 neg value

INTEGER_32

VAR

0x60BC

Touch probe pos 2 pos value

INTEGER_32

VAR

0x60BD

Touch probe pos 2 neg value

INTEGER_32

VAR

Grayed out = read access only

Index

Name

Data type

Object type

0x60B8

Touch probe function

UNSIGNED_16

VAR

0x60B9

Touch probe status

UNSIGNED_16

VAR

0x60BA

Touch probe pos 1 pos value

INTEGER_32

VAR

0x60BB

Touch probe pos 1 neg value

INTEGER_32

VAR

0x60BC

Touch probe pos 2 pos value

INTEGER_32

VAR

0x60BD

Touch probe pos 2 neg value

INTEGER_32

VAR

Advertising