8 detectundervoltage, 9 l_devapplerr1, Detectundervoltage – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 185: L_devapplerr1

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

185

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Parameterisable function blocks

3.21.8

DetectUnderVoltage

3.21.9

L_DevApplErr1

is ans instance of

Function

L_TbCompare_n

DC-bus undervoltage recognition

• Comparison of the current DC-bus voltage with the UG min. threshold set in

C03001

.

Parameter

Possible settings

Information

C04080

Comparison operation

0 dnIn1_n = dnIn2_n
1 dnIn1_n > dnIn2_n
2 dnIn1_n < dnIn2_n

Lenze setting

3 |dnIn1_n| = |dnIn2_n|
4 |dnIn1_n| > |dnIn2_n|
5 |dnIn1_n| < |dnIn2_n|

C04081

0.00

%

100.00 Tolerance

• Initialisation: 0.00 %

C04082

0.00

%

100.00 Hysteresis

• Initialisation: 0.00 %

is ans instance of

Function

L_DevApplErr

Error triggering



Application error messages ( 181)

Parameter

Possible settings

Information

C05900

980

999 Module ID

• Initialisation: 999

C05901/1...8

0

65535 Error ID

• Initialisation: 8001 ... 8008

C05902/1...8

Error response

0 None
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

Advertising