10 position control function, 1 input and output data, Position control function – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 119: Input and output data

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

119

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Position control function

3.10

Position control function

The objects described in this chapter serve to

 control the position control (including following error and in-position recognition),
 control an optional holding brake and
 request the status of the safety functions and safe inputs/outputs of the optional

SM3xx safety module.

3.10.1

Input and output data

Input data

Output data

Index

Name

Data type

Object type

0x60FC

Position demand value*

INTEGER_32

VAR

0x6062

Position demand value

INTEGER_32

VAR

0x6065

Following error window

UNSIGNED_32

VAR

0x6066

Following error time out

UNSIGNED_32

VAR

0x6067

Position window

UNSIGNED_32

VAR

0x6068

Position window time

UNSIGNED_32

VAR

0x60FB

Position control parameter set

UNSIGNED_32

RECORD

Index

Name

Data type

Object type

0x6041

Status word

UNSIGNED_16

VAR

0x6063

Position actual value*

INTEGER_32

VAR

0x6064

Position actual value

INTEGER_32

VAR

0x60F4

Following error actual value

INTEGER_32

VAR

0x60FA

Control effort

INTEGER_32

VAR