EDS94TA11010xxxx EN 1.2 - 03/2010

L

121

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Position control function

0x6064 - Position actual value unit

0x6065 - Following error window

0x6066 - Following error time out

0x6067 - Position window

0x6068 - Position window time

Index | Name:

0x6064 | Position actual value unit

Data type: INTEGER_32

Code:

C03592

Current position in the user-defined [unit]
Display area

(min. value | unit | max. value)

-2147483648

pos unit

2147483647

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX ; PDO_MAP_TX

Index | Name:

0x6065 | Following error window

Data type: UNSIGNED_32

Code:

C03593

Window for following error detection
Setting range

(min. value | unit | max. value)

Lenze setting

0

pos unit

4294967295 0 pos unit

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6066 | Following error time out

Data type: UNSIGNED_32

Code:

C03594

Time monitoring for following error detection

0 = following error is evaluated without time delay.



Following error detection

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

0 0 ms

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6067 | Position window

Data type: UNSIGNED_32

Code:

C03595

Window around the target position for the status message "target position reached"



In-position recognition

Setting range

(min. value | unit | max. value)

Lenze setting

0

pos unit

4294967295 1000 pos unit

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6068 | Position window time

Data type: UNSIGNED_32

Code:

C03596

Time monitoring for the status message "target position reached"

0 = position in the target window is evaluated without time delay.



In-position recognition

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

0 0 ms

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX