9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

104

L

EDS94TA11010xxxx EN 1.2 - 03/2010

CiA402 Homing method 20

Processes:

Case 1:

Axis has not yet activated reference switch:

1. Movement in positive direction with profile data set 1.
2. The following positive edge of reference switch sets reference (

0x607C

).

3. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

Case 2:

Axis already stands on reference switch:

1. Movement in negative direction with profile data set 2.
2. Reversing with negative edge of reference switch.
3. The following positive edge of reference switch sets reference (

0x607C

).

4. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").