0x606c, 0x60b1, 0x60ff – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 151: Object (target

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

151

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Cyclic synchronous velocity mode (IEC 61800-7)

0x606C - Velocity actual value

0x60B1 - Offset velocity

0x60FF - Target velocity

Index | Name:

0x606C | Velocity actual value

Data type: INTEGER_32

Code:

C03653

Current speed
Display area

(min. value | unit | max. value)

-2147483648

vel unit

2147483647

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX ; PDO_MAP_TX

Index | Name:

0x60B1 | Offset velocity

Data type: INTEGER_32

Code:

C03654

Additive value to setpoint for speed or speed feedforward control
Setting range

(min. value | unit | max. value)

Lenze setting

-2147483648

vel unit

2147483647 0 vel unit

;

Read access ; Write access … CINH … PLC-STOP ; PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x60FF | Target velocity

Data type: INTEGER_32

Code:

C03658

Setpoint for speed or speed feedforward control
Setting range

(min. value | unit | max. value)

Lenze setting

-2147483648

vel unit

2147483647 0 vel unit

;

Read access ; Write access … CINH … PLC-STOP ; PDO_MAP_RX … PDO_MAP_TX