9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Assignment of the I/O terminals

3.2.2

Actual value and status signals

The following tables contain the Lenze assignment of the analog and digital outputs for

the "CiA402 device profile" technology application.

Analog outputs

Digital outputs

State bus

Display elements

Terminal X3

Signal (Lenze setting)

Signal configuration

AO1

No signal assigned

C03110/1

AO2

No signal assigned

C03110/2

Terminal X4

Signal (Lenze setting)

Signal configuration

DO1

Brake control (via contactor)

C03100/1

DO2

No signal assigned

• The DO2 digital output can be set via the master control via bit 1

of the

0x60FE/1

object (physical outputs).

C03100/2

DO3

No signal assigned

• The DO3 digital output can be set via the master control via bit 2

of the

0x60FE/1

object (physical outputs).

C03100/3

DO4

No signal assigned

• The DO4 digital output can be set via the master control via bit 3

of the

0x60FE/1

object (physical outputs).

C03100/4

Terminal X2

Signal (Lenze setting)

SB

State bus

• The state bus can be set to the "Fault" status by the master control via bit 4 of the

0x60FE/

1

object (physical outputs).

• The state bus status can be queried via bit 5 of the

0x60FD

object (digital inputs).

User LED

Signal (Lenze setting)
No signal assigned

• The user LED can be controlled by the master control via bit 5 of the

0x60FE/1

object

(physical outputs) (0: LED off, 1: LED on).

GA

AO1

AO2

GO

24O

DO1

DO2

DO3

DO4

GE

24E