0x6076 - Motor rated torque

0x6077 - Torque actual value

0x6078 - Current actual value

0x6079 - DC link circuit voltage

0x6087 - Torque slope

Index | Name:

0x6076 | Motor rated torque

Data type: UNSIGNED_32

Code: C00057/2

Rated motor torque
Display area

(min. value | unit | max. value)

0

mNm

4294967295

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6077 | Torque actual value

Data type: INTEGER_32

Code:

C03677

Current torque

• 2

30

≡ 100 % motor reference torque (C00057/2)

Display area

(min. value | unit | max. value)

-2147483648

_n LENZE

2147483647

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX ; PDO_MAP_TX

Index | Name:

0x6078 | Current actual value

Data type: INTEGER_32

Code:

C03678

Current motor current

• 2

30

≡ 100 % I

max_device

(C00789)

Display area

(min. value | unit | max. value)

-2147483648

_n LENZE

2147483647

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX ; PDO_MAP_TX

Index | Name:

0x6079 | DC link circuit voltage

Data type: UNSIGNED_32

Code: C00053

DC-bus voltage

• Direct mapping of the Lenze code C00053 (DC-bus voltage).
Display area

(min. value | unit | max. value)

0

V

2147483647

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6087 | Torque slope

Data type: UNSIGNED_32

Code:

C03679

Torque change per second

0xffffffff = no torque change per second.
Setting range

(min. value | unit | max. value)

Lenze setting

4294967295

mNm/s

4294967295 0 mNm/s

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX