EDS94TA11010xxxx EN 1.2 - 03/2010

L

167

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Touch probe

0x60B8 - Touch probe function

Index | Name:

0x60B8 | Touch probe function

Data type: UNSIGNED_16

Code:

C03700

Control word for the configuration of the touch probe functionality
Value is bit-coded:

Information

Bit 0 0: Deactivate touch probe 1

1: Activate touch probe 1

Configuration of the touch probe channel 1

Bit 1 0: Record first event only

1: Record all events

Bit 2 Source for touch probe 1

0: Digital input DI7

1: Zero pulse position encoder

Bit 3 Reserved
Bit 4 Evaluation of positive edge

0: Deactivate

1: Activate

Bit 5 Evaluation of negative edge

0: Deactivate

1: Activate

Bit 6 Sequence for edge evaluation if bit 4

and bit 5 = 1

0: -

1: Positive edge - negative edge

Bit 7 Sequence for edge evaluation if bit 4

and bit 5 = 1

0: -

1: Negative edge - positive edge

Bit 8 0: Deactivate touch probe 2

1: Activate touch probe 2

Configuration of touch probe channel 2

Bit 9 0: Record first event only

1: Record all events

Bit 10 Source for touch probe 2

0: Digital input DI8

1: Zero pulse position encoder

Bit 11 Reserved
Bit 12 Evaluation of positive edge

0: Deactivate

1: Activate

Bit 13 Evaluation of negative edge

0: Deactivate

1: Activate

Bit 14 Sequence for edge evaluation if bit

12 and bit 13 = 1

0: -

1: Positive edge - negative edge

Bit 15 Sequence for edge evaluation if bit

12 and bit 13 = 1

0: -

1: Negative edge - positive edge

;

Read access ; Write access … CINH … PLC-STOP ; PDO_MAP_RX … PDO_MAP_TX

Advertising