0x6099, Parameter setting & configuration homing mode – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 77

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

77

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

0x6099 - Homing speeds

Index | Name:

0x6099 | Homing speeds

Data type: UNSIGNED_32

Code:

C03612

For the reference search two speeds can be parameterised to reduce homing time and increase accuracy:

Subindex Name



0x6099/1

Speed during search for switch



0x6099/2

Speed during search for zero

Index | Name:

0x6099/1 | Speed during search for switch

Data type: UNSIGNED_32

Code: C02644

Speed 1 which causes a quick approach of the limit switch/reference switch (depending on the mode selected).

• Direct mapping of the Lenze code C02644 (homing: speed 1).
Setting range

(min. value | unit | max. value)

Lenze setting

0

vel unit

2147483647 0 vel unit

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6099/2 | Speed during search for zero

Data type: UNSIGNED_32

Code: C02646

Speed 2 which causes the touch probe sensor to be approached slower (but more precisely) after reversing on the

limit switch/enabling the reference switch and the subsequent positioning to the target position.

• With "0" setting, the reference search is only executed with speed 1/acceleration 1.

• Direct mapping of the Lenze code C02646 (homing: speed 2).
Setting range

(min. value | unit | max. value)

Lenze setting

0

vel unit

2147483647 0 vel unit

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX