6 common entries, 1 object description, Common entries – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 34: Object description, 0x6007

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Common entries

34

L

EDS94TA11010xxxx EN 1.2 - 03/2010

3.6

Common entries

This chapter describes the general CiA402 parameters.

3.6.1

Object description

All objects correspond to the CiA402 specification, but some of them have only a restricted

value range.

Objects described in this chapter:

0x6007 - Abort connection option code

Index

Name

Data type

Object type

0x6007

Abort connection option code

INTEGER_16

VAR

0x603F

Error code

UNSIGNED_32

VAR

0x6402

Motor type

UNSIGNED_16

VAR

0x6403

Motor catalogue number

VISIBLE_STRING

VAR

0x6404

Motor manufacturer

VISIBLE_STRING

VAR

0x6405

http motor catalogue address

VISIBLE_STRING

VAR

0x6406

Motor calibration date

VISIBLE_STRING

VAR

0x6407

Motor service period

UNSIGNED_32

VAR

0x6410

Motor data

UNSIGNED_32

RECORD

0x6502

Supported drive modes

UNSIGNED_32

BITFIELD

0x6503

Drive catalogue number

VISIBLE_STRING

VAR

0x6504

Drive manufacturer

VISIBLE_STRING

VAR

0x6505

http drive catalogue address

VISIBLE_STRING

VAR

0x6510

Drive data

UNSIGNED_32

RECORD

0x60FD

Digital inputs

UNSIGNED_8

VAR

0x60FE

Digital outputs

UNSIGNED_8

ARRAY

Grayed out = read access only

Index | Name:

0x6007 | Abort connection option code

Data type: INTEGER_16

Code:

C03519

Response to abortion of the communication link.

3 = activate quick stop. 

quick stop

Setting range

(min. value | unit | max. value)

Lenze setting

3

3 3

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Advertising