0x603f, 0x6402, Parameter setting & configuration common entries – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 35

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

35

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Common entries

0x603F - Error code

The following table contains all possible error numbers and their meaning:

0x6402 - Motor type

Index | Name:

0x603F | Error code

Data type: UNSIGNED_32

Code: C00394

Error number
Display area

(min. value | unit | max. value)

0

4294967295

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Error number

Meaning

[dez

[hex]

0

0x0000

Ok, no error

4096

0x1000

An error has occurred in the controller (system fault, fault, trouble, or

warning).

33024

0x8100

Communication error (warning)

33072

0x8130

Network monitoring function "Node guarding" or "Heartbeat" has tripped.

33296

0x8210

PDO length is lower than expected.

33312

0x8220

PDO length is higher than expected.

34560

0x8700

Monitoring of the sync telegram has tripped.

Index | Name:

0x6402 | Motor type

Data type: UNSIGNED_16

Code:

C03503

Motor type
Selection list

(Lenze setting printed in bold)

0 Non-standard motor
1 Phase modulated DC motor
2 Frequency controlled DC motor
3 PM synchronous motor
4 FC synchronous motor
5 Switched reluctance motor
6 Wound rotor induction motor
7 Squirrel cage induction motor
8 Stepper motor
9 Micro-step stepper motor

10 Sinusoidal PM BL motor
11 Trapezoidal PM BL motor

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Advertising