7 profile data set change-over, Profile data set change-over – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 81

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

81

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

3.9.7

Profile data set change-over

For the reference search two profile data sets with different speeds and accelerations can

be parameterised to reduce the homing time and increase the accuracy:

 With the profile data set 1 first the limit switch/reference switch (depending on the

mode selected) is quickly approached.

 After reversing on the limit switch/tripping of the reference switch the profile data set

2 causes the touch probe sensor to be approached slower but more precisely and the

subsequent positioning to the target position (C02643).

[3-9]

Example: profile data set changeover in the homing mode 0

Profile data set 1

Profile data set 2

n

0x6099/1

Speed 1

o

0x6099/2

Speed 2

p

0x609A/1

Acceleration 1

(and deceleration 1)

q

0x609A/2

Acceleration 2

(and deceleration 2)

Reference switch

Reference position

Z-Impulse encoder/

Touch probe sensor

cw

Rn

TP

n

t

Œ



Target position

Ž



Note!

The change-over to the profile data set 2 is only carried out if the speed 2

(

0x6099/2

) is set to > "0"!

In the Lenze setting (

0x6099/2

= "0") no change-over to the profile data set 2

takes place and the reference search and positioning to the target position is

only executed with the profile parameters of the profile data set 1.
The following process descriptions of the homing modes give information about

the time the change over to profile data set 2 takes place in the corresponding

homing mode.

Advertising