9400 Technology applications | CiA402 device profile

Parameter reference

Parameter list | C03583

C03583

C03585

C03590

C03591

C03592

C03593

Parameter | Name:

C03583 | Polarity

Data type: UNSIGNED_8

Index: 20992

d

= 5200

h



CiA402 object

0x607E

Display range

(min. value | unit | max. value)

2

2

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03585 | Load home position

Data type: INTEGER_32

Index: 20990

d

= 51FE

h



CiA402 object

0x60FB.1

Setting range

(min. value | unit | max. value)

Lenze setting

-2147483647

2147483647 0

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03590 | Position demand value unit

Data type: INTEGER_32

Index: 20985

d

= 51F9

h



CiA402 object

0x6062

Display range

(min. value | unit | max. value)

1

255

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03591 | Position actual value

Data type: INTEGER_32

Index: 20984

d

= 51F8

h



CiA402 object

0x6063

Display range

(min. value | unit | max. value)

-2147483647

134217727

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03592 | Position actual value unit

Data type: INTEGER_32

Index: 20983

d

= 51F7

h



CiA402 object

0x6064

Display range

(min. value | unit | max. value)

-2147483647

134217727

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03593 | Following error window

Data type: UNSIGNED_32

Index: 20982

d

= 51F6

h



CiA402 object

0x6065

Setting range

(min. value | unit | max. value)

Lenze setting

0

4294967295 1000

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1