Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 96

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

96

L

EDS94TA11010xxxx EN 1.2 - 03/2010

Case 3:

Axis already stands on reference switch:

1. Movement in positive direction with profile data set 2.
2. Negative edge of the reference switch activates touch probe detection.
3. The following positive edge of the encoder zero pulse/touch probe sensor sets the

reference (

0x607C

).

4. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

CiA402 Homing method 11

Processes:

Case 1:

Axis does not activate reference switch on the way to the limit switch:

1. Movement in negative direction with profile data set 1.
2. Reversing to negative travel range limit switch.
3. Positive edge of the reference switch activates profile data set 2.
4. Negative edge of the reference switch activates touch probe detection.
5. The following positive edge of the encoder zero pulse/touch probe sensor sets the

reference (

0x607C

).

6. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

 Touch probe/zero pulse

 Reference switch

 Negative travel range limit switch

3

1

2

0

1

2

Advertising