10 basic function "homing, Basic function "homing – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 118

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

118

L

EDS94TA11010xxxx EN 1.2 - 03/2010

3.9.10

Basic function "Homing"

In "Homing mode" the "Homing" basic function is used.

Lenze parameters (short overview)

Parameter

Lenze setting

Value Unit

C02528

Traversing range

Modulo

C02640

Homing mode

Set home pos. directly

C02641

Action after detect Home position

Move absolute on Target position

C02642

Home position

0.0000 Unit

C02643

Homing: Target position

0.0000 Unit

C02644

Homing: Speed 1

360.0000 Unit/s

C02645

Homing: Acceleration 1

720.0000 Unit/s

2

C02646

Homing: Speed 2

0.0000 Unit/s

C02647

Homing: Acceleration 2

360.0000 Unit/s

2

C02649

Homing: Torque limit

10.00 %

C02650

Homing: Blocking time

1.000 s

C02652

Ref. pos. after mains switching

Delete

C02653

Max. rot. ang. aft. mns. swtch.

180 °

Advertising