background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

203

9400 Technology applications | CiA402 device profile

Parameter reference

Parameter list | C03534

C03534

C03535

C03536

C03537

C03538

Parameter | Name:

C03534 | Quick stop option code

Data type: INTEGER_16

Index: 21041

d

= 5231

h



CiA402 object

0x605A

Setting range

(min. value | unit | max. value)

Lenze setting

2

2 2

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03535 | Halt option code

Data type: INTEGER_16

Index: 21040

d

= 5230

h



CiA402 object

0x605D

Setting range

(min. value | unit | max. value)

Lenze setting

2

2 2

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03536 | Fault reaction option code

Data type: INTEGER_16

Index: 21039

d

= 522F

h



CiA402 object

0x605E

Setting range

(min. value | unit | max. value)

Lenze setting

2

2 2

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03537 | Mode of operation

Data type: INTEGER_8

Index: 21038

d

= 522E

h



CiA402 object

0x6060

Selection list

(Lenze setting printed in bold)

0 no mode
6 Homing mode
7 Interpolated position mode
8 Cyclic synchronous position mode
9 Cyclic synchronous velocity mode

10 Cyclic synchronous torque mode

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03538 | Mode of operation display

Data type: INTEGER_8

Index: 21037

d

= 522D

h



CiA402 object

0x6061

Selection list

(display only)

0 no mode
6 Homing mode
7 Interpolated position mode
8 Cyclic synchronous position mode
9 Cyclic synchronous velocity mode

10 Cyclic synchronous torque mode

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1