Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 113

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

113

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

CiA402 Homing method 29

Processes:

Case 1:

Axis does not activate reference switch on the way to the limit switch:

1. Movement in negative direction with profile data set 1.
2. Reversing to negative travel range limit switch.
3. The following positive edge of reference switch sets reference (

0x607C

).

4. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

Case 2:

Axis activates reference switch first on the way to the limit switch:

1. Movement in negative direction with profile data set 1.
2. Positive edge of the reference switch activates profile data set 2.
3. Reversing with negative edge of reference switch.
4. The following positive edge of reference switch sets reference (

0x607C

).

5. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

Case 3:

Axis already stands on reference switch:

1. Movement in negative direction with profile data set 2.
2. Reversing with negative edge of reference switch.
3. The following positive edge of reference switch sets reference (

0x607C

).

4. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

 Homing switch

 Negative travel range limit switch

1

3

2

0

1

Advertising