Operating mode changeover

The drive behaviour depends on the operating mode selected. The operating mode

changeover is executed via the

0x6060

object (mode of operation) in the communication

states PREOPERATIONAL or OPERATIONAL by the master control. Access is possible via SDO

or PDO.

 Only one operating mode at a time can be active.
 Except for the "Homing Mode" the operating modes differ in the way the setpoints are

selected.

 The following table shows the permissible operating modes with the corresponding

object value:

Tip!
The currently set operating mode can be read via the

0x6061

object (mode of

operation display). Here, access is also possible via SDO or PDO.
Except for the source of the setpoint selection, the operating mode "

Interpolated

position mode

" corresponds to the operating mode "Cyclic synchronous position

mode".

Operating mode

Object value

Setpoint selection

Homing mode

6

- (Homing function)

Interpolated position mode

7

Position

Cyclic synchronous position mode (IEC 61800-7)

8

Position

Cyclic synchronous velocity mode (IEC 61800-7)

9

Speed

Cyclic synchronous torque mode (IEC 61800-7)

10

Torque

-

All other values

- (Standstill)