EDS94TA11010xxxx EN 1.2 - 03/2010

L

205

9400 Technology applications | CiA402 device profile

Parameter reference

Parameter list | C03556

C03556

C03557

C03558

C03559

C03560

C03561

Parameter | Name:

C03556 | Position encoder resolution

Data type: UNSIGNED_32

Index: 21019

d

= 521B

h



CiA402 object

0x608F

Display range

(min. value | unit | max. value)

0

4294967295

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03557 | Encoder increments

Data type: UNSIGNED_32

Index: 21018

d

= 521A

h



CiA402 object

0x608F.1

Setting range

(min. value | unit | max. value)

Lenze setting

65536

65536 65536

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03558 | Motor revolution

Data type: UNSIGNED_32

Index: 21017

d

= 5219

h



CiA402 object

0x608F.2

Setting range

(min. value | unit | max. value)

Lenze setting

1

1 1

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03559 | Velocity encoder resolution

Data type: UNSIGNED_32

Index: 21016

d

= 5218

h



CiA402 object

0x6090

Display range

(min. value | unit | max. value)

2

2

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03560 | Encoder increments per second

Data type: UNSIGNED_32

Index: 21015

d

= 5217

h



CiA402 object

0x6090.1

Setting range

(min. value | unit | max. value)

Lenze setting

65536

65536 65536

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03561 | Motor revolutions per second

Data type: UNSIGNED_32

Index: 21014

d

= 5216

h



CiA402 object

0x6090.2

Setting range

(min. value | unit | max. value)

Lenze setting

1

1 1

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Advertising