Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 176

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Internal interfaces | function block "L_CiA402DeviceProfile"

176

L

EDS94TA11010xxxx EN 1.2 - 03/2010

3.19

Internal interfaces | function block "L_CiA402DeviceProfile"

The L_CiA402DeviceProfile function block contains the main functionality of the CiA402

device profile.

Inputs

Identifier

Data type

Information/possible settings

wCiA402ControlWord

WORD

Interface of the master / master control

• Control word (

0x6040

).



Device control commands

byCiA402ModeOfOperation

BYTE

Interface of the master / master control

• Selection of the operating mode (

0x6060

).



Operating mode changeover

dnCiA402SetPosition_e4

DINT

Interface of the master / master control

• Selection of the setpoint position in user units (e4 representation) for

Interpolated position mode

.

dnCiA402TargetPosition_e4

DINT

Interface of the master / master control

• Selection of the setpoint position in user units (e4 representation) for

Cyclic

synchronous position mode (IEC 61800-7)

.

dnCiA402OffsetPosition_e4

DINT

Interface of the master / master control

• Selection of a position offset in user units (e4 representation).

dnCiA402TargetSpeed_e4

DINT

Interface of the master / master control

• Selection of a set speed in user units (e4 representation).

dnCiA402OffsetSpeed_e4

DINT

Interface of the master / master control

• Selection of a speed offset in user units (e4 representation).

dnCiA402TargetTorque_n

DINT

Interface of the master / master control

• Selection of a torque in [%].

• 2

30

≡ 100 % ≡ C00057/2

dnCiA402OffsetTorque_n

DINT

Interface of the master / master control

• Selection of a torque offset in [%].

• 2

30

≡ 100 % ≡ C00057/2

wCiA402PosTorqueLimit_a

WORD

Interface of the master / master control

• Selection of the positive torque limit in [%].

• 2

16

≡ 100% ≡ C00057/2

wCiA402NegTorqueLimit_a

WORD

Interface of the master / master control

• Selection of the negative torque limit in [%].

• 2

16

≡ 100% ≡ C00057/2

byCiA402DigitalOutput

BYTE

Interface of the master / master control

• Selection of the states of the digital outputs.

dnHM_dnState

DINT

Interface for the "homing" basic function

• Input for the status signal of the basic function.

• Connect this input to the HM_dnState output of the LS_Homing system block.

bHM_bEnabled

BOOL

Interface for the "homing" basic function

• Input for the status signal "enable homing basic function".

• Connect this input to the HM_bEnabled output of the LS_Homing system block.

bHM_bActive

BOOL

Interface for the "homing" basic function

• Input for the status signal "homing basic function active".

• Connect this input to the HM_bActive output of the LS_Homing system block.

bHM_bDone

BOOL

Interface for the "homing" basic function

• Input for the status signal "homing completed".

• Connect this input to the HM_bDone output of the LS_Homing system block.

bHM_bHomePosAvailable

BOOL

Interface for the "homing" basic function

• Input for the status signal "home position available".

• Connect this input to the HM_bHomePosAvailable output of the LS_Homing

system block.