2 object description, Object description, 0x6062 – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 120: 0x6063

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Position control function

120

L

EDS94TA11010xxxx EN 1.2 - 03/2010

3.10.2

Object description

Except for the

0x60FA

object (control effort), all objects correspond to the CiA402

specification.

Objects described in other chapters:

Objects described in this chapter:

0x6062 - Position demand value unit

0x6063 - Position actual value*

Index

Name

Data type

Object type



Device control

0x6041

Status word

UNSIGNED_16

VAR

Grayed out = read access only

Index

Name

Data type

Object type

0x6062

Position demand value unit

INTEGER_32

VAR

0x6063

Position demand value unit

INTEGER_32

VAR

0x6064

Position actual value unit

INTEGER_32

VAR

0x6065

Following error window

UNSIGNED_32

VAR

0x6066

Following error time out

UNSIGNED_32

VAR

0x6067

Position window

UNSIGNED_32

VAR

0x6068

Position window time

UNSIGNED_32

VAR

0x60F4

Following error actual value

INTEGER_32

VAR

0x60FA

Control effort

INTEGER_32

VAR

0x60FB

Position control parameter set

UNSIGNED_32

RECORD

0x60FC

Position demand value*

INTEGER_32

VAR

Grayed out = read access only

Index | Name:

0x6062 | Position demand value unit

Data type: INTEGER_32

Code:

C03590

Interpolated position setpoint for position control in the user-defined [unit]
Display area

(min. value | unit | max. value)

-2147483648

pos unit

2147483647

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6063 | Position actual value*

Data type: INTEGER_32

Code:

C03591

Current position in [increments]
Display area

(min. value | unit | max. value)

-2147483648

inc

2147483647

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX ; PDO_MAP_TX

Advertising