9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Device control

3.7.3.1

Not ready to switch on

This is the controller status directly after switching on the supply voltage.

 In this device state the operating system is initialised.
 The monitorings are not active yet.
 Communication is not possible yet.
 The controller cannot be parameterised yet and no device commands can be executed.
 The motor brake, if available, is closed.
 The operation is inhibited.

Bit pattern for "Not ready to switch on" device state in

0x6041

(status word):

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Warning

Switch on

disabled

Quick stop

Voltage

enabled

Fault

Operation

enabled

Switched on

Ready to switch

on

X

0

X

X

0

0

0

0

Note!

When the device initialisation is completed, the device state is automatically

changed to "

Switch on disabled

".