C03636 | interpolation time period, C03637 | ip time units, C03638 | ip time index – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 213: C03639 | interpolation sync definition, C03640 | synchronize on group, C03641 | ip sync every n event, Code, C03636, C03637, C03638

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

213

9400 Technology applications | CiA402 device profile

Parameter reference

Parameter list | C03636

C03636

C03637

C03638

C03639

C03640

C03641

Parameter | Name:

C03636 | Interpolation time period

Data type: UNSIGNED_32

Index: 20939

d

= 51CB

h



CiA402 object

0x60C2

Display range

(min. value | unit | max. value)

2

2

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03637 | Ip time units

Data type: UNSIGNED_8

Index: 20938

d

= 51CA

h



CiA402 object

0x60C2.1

Setting range

(min. value | unit | max. value)

Lenze setting

0

255 1

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03638 | Ip time index

Data type: INTEGER_8

Index: 20937

d

= 51C9

h



CiA402 object

0x60C2.2

Setting range

(min. value | unit | max. value)

Lenze setting

-6

0 -3

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03639 | Interpolation sync definition

Data type: UNSIGNED_8

Index: 20936

d

= 51C8

h



CiA402 object

0x60C3

Display range

(min. value | unit | max. value)

2

2

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03640 | Synchronize on group

Data type: UNSIGNED_8

Index: 20935

d

= 51C7

h



CiA402 object

01x60C3.1

Setting range

(min. value | unit | max. value)

Lenze setting

0

0 0

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03641 | Ip sync every N event

Data type: UNSIGNED_8

Index: 20934

d

= 51C6

h



CiA402 object

0x60C3.2

Setting range

(min. value | unit | max. value)

Lenze setting

1

1 1

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Advertising