0x6088, 0x60b2, 0x60f6 – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 160: Object (torque

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Cyclic synchronous torque mode (IEC 61800-7)

160

L

EDS94TA11010xxxx EN 1.2 - 03/2010

0x6088 - Torque profile type

0x60B2 - Torque offset

0x60F6 - Torque control parameters

Index | Name:

0x6088 | Torque profile type

Data type: INTEGER_16

Code:

C03680

Torque profile

0 = Linear ramp (interpolation).
Setting range

(min. value | unit | max. value)

Lenze setting

0

0 0

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x60B2 | Torque offset

Data type: INTEGER_32

Code:

C03683

Additive value to setpoint for torque or torque feedforward control

• 2

30

≡ 100 % motor reference torque (C00057/2)

Setting range

(min. value | unit | max. value)

Lenze setting

-2147483648

_n LENZE

2147483647 0 _n LENZE

;

Read access ; Write access … CINH … PLC-STOP ; PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x60F6 | Torque control parameters

Data type: UNSIGNED_32

Code:

C03682

Parameter for torque control

Subindex Name



0x60F6/1

Positive speed limit



0x60F6/2

Negative speed limit

Index | Name:

0x60F6/1 | Positive speed limit

Data type: INTEGER_32

Code:

C03684

Upper speed limit value in [%] for speed limitation

• For positive direction of motion.

• 100 % ≡ Motor reference speed (C00011).

• Negative values are limited internally to the value "0".
Setting range

(min. value | unit | max. value)

Lenze setting

0

%

175.00 100.00 %

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x60F6/2 | Negative speed limit

Data type: INTEGER_32

Code:

C03685

Lower speed limit value in [%] for speed limitation

• For negative direction of motion.

• 100 % ≡ Motor reference speed (C00011).

• Positive values are limited internally to the value "0".
Setting range

(min. value | unit | max. value)

Lenze setting

-175.00

%

0 -100.00 %

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Advertising