9 homing mode, Homing mode – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 73

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

73

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

3.9

Homing mode

In this operating mode, homing can be executed to transmit the measuring system of the

machine to the controller within the physically possible travel range.

Selection of operating mode
The "Homing" operating mode is selected via the

0x6060

object (mode of operation) using

the value "6".

Danger!

During homing operations, specially assigned profile parameters are effective. If

these parameters are not set correctly, the drive may execute uncontrolled

movements!

Note!

Normally homing is only required once during commissioning of systems for

which the machine cycle can be represented in the display area of the encoder,

e.g. if multiturn absolute value encoders or singleturn absolute value encoders/

resolvers are used during the machine cycle on one motor revolution.
• The encoder position is stored safe against mains failure in the memory

module and is therefore known to the drive control even after the mains has

been switched.

• Another reference setting is only required in the case of another

commissioning or in the event of service (e.g. when drive components are

replaced).