3 short overview of the cia402 objects, 1 object directory, 2 cia402 objects – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 18: Short overview of the cia402 objects, Object directory, Cia402 objects

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Short overview of the CiA402 objects

18

L

EDS94TA11010xxxx EN 1.2 - 03/2010

3.3

Short overview of the CiA402 objects

3.3.1

Object directory

The object directory for the CiA402 device profile is divided into the following subareas:

3.3.2

CiA402 objects

Object area

Description

Common entries

General objects

Device control

Objects for the drive control

Factor group

Objects for scaling the position, speed, and acceleration

Position control function

Objects for positioning

Homing mode

Objects for homing

Interpolated position mode

Objects for "Interpolated position mode"

Cyclic synchronous position mode (IEC 61800-7)

Objects for controlling the position

Cyclic synchronous torque mode (IEC 61800-7)

Objects for controlling the torque

Cyclic synchronous velocity mode (IEC 61800-7)

Objects for controlling the speed

Touch probe

Objects for the touch probe functionality

Torque limiting

Objects for selecting the torque limit values

Index

Name

(Subindex: designation)

Data type

Object type

Common entries

0x6007

Abort connection option code

INTEGER_16

VAR

0x603F

Error code

UNSIGNED_32

VAR

0x6402

Motor type

UNSIGNED_16

VAR

0x6403

Motor catalogue number

VISIBLE_STRING

VAR

0x6404

Motor manufacturer

VISIBLE_STRING

VAR

0x6405

http motor catalogue address

VISIBLE_STRING

VAR

0x6406

Motor calibration date

VISIBLE_STRING

VAR

0x6407

Motor service period

UNSIGNED_32

VAR

0x6410

Motor data

UNSIGNED_32

RECORD

0x6502

Supported drive modes

UNSIGNED_32

VAR

0x6503

Drive catalogue number

VISIBLE_STRING

VAR

0x6504

Drive manufacturer

VISIBLE_STRING

VAR

0x6505

http drive catalogue address

VISIBLE_STRING

VAR

0x6510

Drive data

UNSIGNED_32

RECORD

0x60FD

Digital inputs

UNSIGNED_8

VAR

0x60FE

Digital outputs

UNSIGNED_8

ARRAY

1: Physical outputs

UNSIGNED_8

2: Bit mask

UNSIGNED_8

Grayed out = read access only