0x608f, 0x6090, Parameter setting & configuration factor group – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 67

Advertising
background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

67

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Factor group

0x608F - Position encoder resolution

0x6090 - Velocity encoder resolution

Index | Name:

0x608F | Position encoder resolution

Data type: UNSIGNED_32

Code:

C03556

Resolution of the position encoder

Subindex Name



0x608F/1

Encoder increments



0x608F/2

Motor revolution

Index | Name:

0x608F/1 | Encoder increments

Data type: UNSIGNED_32

Code:

C03557

Incremental encoder pulses
Setting range

(min. value | unit | max. value)

Lenze setting

65536

inc

65536 65536 inc

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x608F/2 | Motor revolution

Data type: UNSIGNED_32

Code:

C03558

Number of motor revolutions
Setting range

(min. value | unit | max. value)

Lenze setting

1

rev

1 1 rev

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6090 | Velocity encoder resolution

Data type: UNSIGNED_32

Code:

C03559

Resolution of the speed encoder

Subindex Name



0x6090/1

Encoder increments per second



0x6090/2

Motor revolutions per second

Index | Name:

0x6090/1 | Encoder increments per second

Data type: UNSIGNED_32

Code:

C03560

Incremental encoder pulses per second
Setting range

(min. value | unit | max. value)

Lenze setting

65536

inc/s

65536 65536 inc/s

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6090/2 | Motor revolutions per second

Data type: UNSIGNED_32

Code:

C03561

Number of motor revolutions per second
Setting range

(min. value | unit | max. value)

Lenze setting

1

rev/s

1 1 rev/s

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Advertising