EDS94TA11010xxxx EN 1.2 - 03/2010

L

201

9400 Technology applications | CiA402 device profile

Parameter reference

Parameter list | C03514

C03514

C03515

C03516

C03517

C03518

C03519

Parameter | Name:

C03514 | Supported drive modes

Data type: UNSIGNED_32

Index: 21061

d

= 5245

h



CiA402 object

0x6502

Display range

(min. value | unit | max. value)

0

4294967295

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03515 | Digital inputs

Data type: UNSIGNED_8

Index: 21060

d

= 5244

h



CiA402 object

0x60FD

Display range

(min. value | unit | max. value)

0

255

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03516 | Digital outputs

Data type: UNSIGNED_8

Index: 21059

d

= 5243

h



CiA402 object

0x60FE

Display range

(min. value | unit | max. value)

2

2

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03517 | Physical outputs

Data type: UNSIGNED_8

Index: 21058

d

= 5242

h



CiA402 object

01x60FE.1

Display range

(min. value | unit | max. value)

0

255

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03518 | Bit mask

Data type: UNSIGNED_8

Index: 21057

d

= 5241

h



CiA402 object

0x60FE.2

Setting range

(min. value | unit | max. value)

Lenze setting

255

255 255

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C03519 | Abort connection option code

Data type: INTEGER_16

Index: 21056

d

= 5240

h



CiA402 object

0x6007

Setting range

(min. value | unit | max. value)

Lenze setting

3

3 3

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Advertising