9400 Technology applications | CiA402 device profile

Parameter setting & configuration

3

Parameter setting & configuration

Tip!
For quick reference of a CiA402 object with a certain name simply use the Index of

this online documentation. In the index, the corresponding CiA402 object is always

given in brackets behind the name.
For general information on how to read and change parameters please see the

online documentation for the »Engineer«.

Note!

In general, the "Warning locked" error response should not be set for the

operation of the CiA402 application with a control because the control cannot

distinguish this error response from the "Warning" error response. Therefore, it

cannot be acknowledged.

Conventions for CiA402 objects
The indexes of the CiA402 objects are indicated in the online documentation in

hexadecimal notation with a prefixed "0x", e.g. "

0x6040

".

Some CiA402 objects (of the ARRAY or RECORD object type) contain so-called

"subindexes" in which the CiA402 parameters are stored. The slash "/" is used in

this online documentation as a separator between the index data and the

subindex, e.g. "

0x60FB/7

".