9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Position control function

0x60FC - Position demand value*

Index | Name:

0x60FB/7 | Homing stop mode

Data type: UNSIGNED_32

Code: C02641

Drive behaviour after setting the home position

• Direct mapping of the Lenze code C02641 (behaviour after detection of home position)



Drive behaviour after setting the home position

Selection list

(Lenze setting printed in bold)

Information

0 Move absolute on Target position

After setting the home position (C02642), the drive

moves to the absolute target position set in C02643.

• This selection is the Lenze setting and corresponds to

the behaviour known from the previous versions.

1 Move relative by Target position

After setting the home position (C02642), the drive

moves relatively by the target position set in C02643.

2 Stop

After setting the home position (C02642), the drive stops

immediately.

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x60FC | Position demand value*

Data type: INTEGER_32

Code:

C03600

Interpolated position setpoint for position control in [increments]
Display area

(min. value | unit | max. value)

-2147483648

inc

2147483647

;

Read access … Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX