Outputs – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 178

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Internal interfaces | function block "L_CiA402DeviceProfile"

178

L

EDS94TA11010xxxx EN 1.2 - 03/2010

Outputs

bMI_

bMotorOrientationInverse

BOOL

Interface for the motor interface

• Input for the motor mounting position.

• Connect this input to the MI_bMotorOrientationInverse output of

the LS_MotorInterface system block.

bMI_

bSpeedBelowThresholdC19

BOOL

Interface for the motor interface

• Input for the zero speed recognition.

• Connect this input to the bSpeedBelowThresholdC19 output of the

LS_MotorInterface system block.

bPF_bEnabled

BOOL

Interface for the "position follower" basic function

• Input for the status signal "position follower basic function active".

• Connect this input to the PF_bEnabled output of the LS_Positionfollower system

block.

bSF_bEnabled

BOOL

Interface for the "speed follower" basic function

• Input for the status signal "speed follower basic function active".

• Connect this input to the SF_bEnabled output of the LS_Speedfollower system

block.

bTF_bEnabled

BOOL

Interface for the "torque follower" basic function

• Input for the status signal "torque follower basic function active".

• Connect this input to the TF_bEnabled output of the LS_Torquefollower system

block.

dnSMI_dnState

DINT

Interface for the safety module

• Input for the status signal.

• Connect this input to the SMI_bEnabled output of the LS_SafetyModulinterface

system block.

bSYNC_

bProcessDataExpected

BOOL

Input for the status information "process data expected"

• Connect this input to the SYNC_bProcessDataExpected output of

the LS_SyncInput system block.

bSYNC_

bProcessDataInvalid

BOOL

Input for the status information "process data invalid"

• Connect this input to the SYNC_bProcessDataInvalid output of the LS_SyncInput

system block.

byDigitalInput

BYTE

Input for the acceptance of the status of the digital inputs

bySafeIOState

BYTE

Input for the acceptance of the I/O status of the safety module

AxisData

Input for transfer of the machine parameters of the drive

• Connect this input to the output DI_AxisData of the system

block LS_DriveInterface.

Identifier

Data type

Info/meaning

wCiA402StatusWord

WORD

Interface to the master / master control

• Status word (

0x6041

).



Device statuses

byCiA402

ModeOfOperationDisplay

BYTE

Interface to the master / master control

• Active operating mode (

0x6061

).



Operating mode changeover

dnCiA402ActualPosition_e4

DINT

Interface to the master / master control

• Actual position in user units (e4 representation).

dnCiA402ActualPosition_p

DINT

Interface to the master / master control

• Actual position in internal units.

dnCiA402

ActualFollowingError_e4

DINT

Interface to the master / master control

• Actual following error in user units (e4 representation).

Identifier

Data type

Information/possible settings

Advertising