2 torque feedforward control, Torque feedforward control – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 130

Advertising
background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Position control function

130

L

EDS94TA11010xxxx EN 1.2 - 03/2010

3.10.6.2

Torque feedforward control
In automatic operation (mode 2/12) the brake control offers the possibility of

precontrolling the required torque of the drive when the brake is released.

Via C02588 it is selected whether a parameterised starting torque or the torque

memorised during the last closing operation shall be used for the feedforward control.

 When setting C02588 = 0, bit 1 of the

0x60FB/2

object (brake control) can be used to

switch between two starting torques:
– Bit 1 = 0: starting torque 1 (C02586) is used.
– Bit 1 = 1: starting torque 2 (C02587) is used.

 When C02588 = 1, the starting torque is the setpoint which has been automatically

memorised during the last closing process (falling below the speed threshold set in

C02581).

[3-12] Torque feedforward control

Note!

The torque is precontrolled for one second. During this time, the actual torque

must have reached 90 % of the set torque, otherwise a fault is tripped!

Note!

The higher the threshold for brake activation set in C02581, the higher is the

dynamic part in the memorised torque (e.g. the speed-dependent friction

torque).
In the special case that the load changes when the brake is closed, a correction

value, which is added to the memorised torque, can be defined for the torque

feedforward control via the

0x60FB/3

object (brake torque add).

n

C02586: Starting torque 1

o

C02587: Starting torque 2

p

C02588: Starting torque source

1

0

BRK_bStartingTorque2

C02586

Œ


C02587

1

0

C02588 = 0

Ž

S&H

CTRL

Speed controller

Brake control

0x60FB/2

BRK_dnTorqueAdd_n

Brake torque add

0x60FB/3

Bit 1

Advertising