9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Application error messages

3.20

Application error messages

In order to output application-specific error messages, a L_DevApplErr1 FB instance of the

L_DevApplErr function block is provided in the interconnection.

 Up to 8 different application error messages with parameterisable module ID, error ID

and error response can be triggered by the application via the 8 boolean inputs.

 The first two inputs are fixed connected to trigger signals of the application, the other

six inputs are free:

 Parameterisation: all parameters tab

Error message

Error ID

Error response

1

DC-bus undervoltage

8001

Quick stop by trouble

2

Maximal value of the telegram failure exceeded

8002

Information

3

Application error (free input)

8003

Error

4

Application error (free input)

8004

Error

5

Application error (free input)

8005

Error

6

Application error (free input)

8006

Error

7

Application error (free input)

8007

Error

8

Application error (free input)

8008

Error

Parameter

Lenze setting

C05900

Module ID

999

C05901/1...8

Error ID 1 ... 8

see table above

C05902/1...8

Error response 1 ... 8

see table above

Note!

In general, the "Warning locked" error response should not be set for the

operation of the CiA402 application with a control because the control cannot

distinguish this error response from the "Warning" error response. Therefore, it

cannot be acknowledged.