Machine constants

Technology−specific settings

MK_MFKT_UPR_TABELLE

4

4.15

4.15.1

l

221

EDSTCXN EN 2.0

4.15

Technology−specific settings

4.15.1

MK_MFKT_UPR_TABELLE

This machine constant is a list of up to 16 M function numbers, which
generate a branch in a subprogram during processing within a DIN program.
A difference is made between the following cases:

Value

Meaning

< 500

When the configured M function appears in the program, a subprogram call with
the program number 9000 + M function number is inserted subsequently. The
programmed M function is output before the first executable block of the
subprogram is executed.

500
600
700
800
900

Each of these values stands for the following 99 M function numbers. Every time
one of these 100 M functions appears in the program, the M function is replaced
with the program number 9000 + basic M function number by means of a
subprogram call. Therefore, M621 becomes G22 L9600. The programmed M
function is not output. Therefore, no processing time is required in the PLC for the
M function.

The M function, which lead to the subprogram call, is stored in the parameter
field in P562 for NC channel 0 and in P594 for channel N. It can be evaluated
in the subprogram.

For further information, refer to chapter "M functions" (

175).

4.15.2

MK_TECHNOLOGIEDATEN1 ... MK_TECHNOLOGIEDATEN4

These machine constants contain 10 entries each, which are stored
one−to−one in the parameter field of P760 ... P799 where they can be used as
required. For the assignment of the parameter field, refer to chapter "P field"
(

180).