Machine constants, List of machine constants – Lenze ETC Motion Control User Manual

Page 231

Advertising
background image

Machine constants

List of machine constants

4

4.16

l

231

EDSTCXN EN 2.0

1234,

/* input number of the neg. limit switch */

1234;

/* input number of the pos. limit switch */

MK_US

0,

/* monitor. of the position encoder protection signal */

0,

/* 1 = monitoring active, 0 = inactive */

0,

0,

0,

0;

MK_UA0

0,

/* cable breakage monitoring, position encoder zero pulse */

0,

/* 1 = monitoring active, 0 = inactive */

0,

0,

0,

0;

MK_UA12

0,

/* cable breakage monitoring, position encoder signal Ua1/Ua2
*/

0,

/* 1 = monitoring active, 0 = inactive */

0,

/* 2 = ignore nonrecurring fault */

0,

0,

0;

MK_TEACHACHSE

1,

/* marking of axes that are to be */

1,

/* transferred via the teach−in box */

1,

/* during teaching */

0,

0,

0;

MK_MASSSTAB

1,

/* multiplication factor for the position */

1,

/* programmed in a DIN block */

1,

1,

1,

1;

MK_HANDRADZUORDNUNG

0,

/* assignment of axes to handwheels */

0,

/* 0 = handwheel 0, 1 = handwheel 1 */

0,

0,

0,

0;

MK_HANDRADFAKTOR

1,

/* individual evaluation factor for the */

1,

/* handwheel funct., e.g. for special treatment */

1,

/* of rotation axes */

1,

1,

1;