Getting started – Lenze ETC Motion Control User Manual

Page 74

Advertising
background image

Getting started

Testing CNC and PLC program

2

2.13

l

74

EDSTCXN EN 2.0

If 24 V is not applied to one of the two inputs in time, the program stops and
the following error message appears in a red box.

ETCN036

This error message is generated via the SPSERROR function in the PLC_KEYS
module after a timer of 5 s has elapsed. The text belonging to the error
number is contained in the file "sps_fehl.db" (English version:
"sps_erro.db"). This file is located in the directory "cfg" of the ETC−MMI.

The figure shows an error from the control system (2) of the PLC program
module (10) with the error number 400 (F_TOOL_UP_KI). For a correct error
message, an error number 2.10.400 with the corresponding text must be
entered in the file "sps_fehl.db".

Error messages of the CNC
program

Advertising