PLC programming

Library

V24 functions

8

8.8

8.8.2

l

379

EDSTCXN EN 2.0

8.8.2.4

READBLOCKV24

FUNCTION ReadBlockV24: DINT

VAR_INPUT

pRequest

: DINT;

(* Address of the V24 request structure *)

pBuffer

: DINT;

(* Address of a data buffer *)

BufSize

: INT;

(* Buffer size in byte *)

END_VAR

The function reads max. BufSize characters in the stated data buffer pBuffer
from the V24 reception buffer.

The function returns the number of characters read from the reception
buffer.

8.8.2.5

READV24

FUNCTION ReadV24: DINT

VAR_INPUT

req_pr

: DINT;

(* Address of the V24 request structure *)

END_VAR

Reading a character from the reception buffer. The reception buffers is
implemented as FIFO and is read and written to simultaneously.

This function always provides an immediate return. Return values smaller
than 0 indicate an error (

391). If the FIFO is empty, −1 (EOF) will be

returned.

requestV24_p

: DINT;

zeichen_di

: DINT;

zeichen_di

: = READV24(requestV24_p);

8.8.2.6

WRITEBLOCKV24

FUNCTION WriteBlockV24: DINT

VAR_INPUT

pRequest

: DINT;

(* Address of the V24 request structure *)

pBuffer

: DINT;

(* Address of a data buffer *)

BufSize

: INT;

(* number of the characters to be written *)

END_VAR

The function tries to insert BufSize characters of the stated address pBuffer
into the V24 send buffer. If there is sufficient space in the send buffer all
BufSize characters will be entered.

The function returns the number of the characters written into the send
buffer.

Declaration

Description

Declaration

Description

Example

Declaration

Description